SibER 48
Since 2013 – 4-th generation of electrical exploration equipment “SibER-48” has following features:
1. Improved feedback circuit generator that allows you to work without interruption at no load and short-circuit;
2. Reduced measurement time;
3. Values increased mechanical strength of bearing structures;
4. Applied more reliable switch interface boards;
5. Improved performance of the generator;
6. Added protection against overheating of the transformer.
New generation of the device has successfully passed the tests field trials, as well as vibration test, shock and environmental testing in accordance with GOST 26116-84 .
Measurement with Siber-48 based on the resistivity methods. The fundamental physical law used in resistivity surveys is Ohm’s Law that governs
the flow of current in the ground. With equipment it is possible to work in 2D Electrotomography and Induced polarization modes.
Electrical exploration equipment “Siber-48” has built-in software that lets you :
– Program the switches for 2D Tomography;
– Ensure the safety of data when power failure;
– Perform control for each electrodes;
– Provides flexible equipment control.
For long profiles implemented mode “scolding Profile” with the transfer of the first segment of the multielectrode cable previous arrangement on the second place in the next.
Software for PC – SibER Tools, needs to create and edit files with descriptions of the sequences, as well as primary data processing – filtering, packaging and export to common formats (IPI2Win, Res2dInv, Res3dInv). The program allows you to create sequences for both measurements electro-tomography and traditional four-electrode sounding with linear or geometric step spacing.
Manufactured by KB “Electometry”
General parameters Number of electrodes – 48 External power – 12 V Internal battery – 12 V, 7 Ah Sensor display – 12″, 240 x 128 Inner memory up to – 2 Гб PC connection – USB 2.0 Ingress Protection Rating with closed cover – IP 67 Ingress Protection Rating with opened cover – IP 54 Operating temperature – from -20 ro +40 °C Dimensions 420 x 340 x 230 mm Weight 11 кг
|
Receiver Number of measurement channels – 1 Input resistance – 10 Mom Bandwidth – 20 Hz The range of measured voltages – from ±0.1 mV to ±250 V Industrial frequency interference mitigation 50,60 Hz – 65 dB Voltage measurement accuracy- 1 % ADC – 24 bit Overvoltage protection to – 1 kV
|
Transmitter Operating frequencies – 3.33, 0.86, 0.78, 0.74, 0.69, 0.66, 0.60 Hz Output current- 1 ÷ 2000 mA Maximum power – 200 W Current measurement accuracy- 1 % Maximum voltage – 500 V Protection against short circuit – yes
|
Measuring settings Wenner (α, β, γ configuration), Schlumberger, dipole axis, three-electrode (forward and reverse configuration), two-electrode and their mutual counterparts who feed and measuring electrodes are swapped
|
Operating Modes Resistivity method – yes Induced polarization method (IP) – yes Connecting an external switch – no Connecting an external oscillator – no
|
[modernised into SibER 48K12] |
Instruction Manual for Siber-48 |
|
SibER Tools |
|
“RiPPP” for resistivity and IP data preliminary processing – Ver 1.12 |
|
SibER Tools is the software pack for create and edit files with descriptions of the settings, as well as primary data processing – filtering, packaging and export to common formats (IPI2Win, Res2dInv, Res3dInv). The program allows you to create templates for both measurements electrical tomography and traditional four-electrode sounding with linear or geometric step spacing.
RiPPP is intended for resistivity and IP data preliminary processing. RiPPP allows
to view, to link, to filter the data and to export preliminary processing results
to other formats.
– Agronomy
– Engineering Geology
– Ecology
– Archaeology
– Utilities
– Reclamation
– Hydrogeology
– Special tasks